Home > Compact Solar System > Heat Pipe Pressurized System

200Liter Compact Pressurized Solar Water Heater


200Liter compact pressurized solar water heater  with aluminium alloy frame details: 
Model: FD-AIP-24

 

Compact pressurized solar water heater features

1.Adopts the best conduction performance metal- heat pipe (copper) 
2.Can be used all year round in the cold climate
3.High efficiency, rapid warming. Heat pipe in vacuum tube could transfer hot energy to cold water in pressurized solar water heater tank rapidly
4.The whole pressure of the system is up to 1.5kg/M2, the inlet could connect the tap water directly, the max pressure can be 0.6Mpa 
5.No water in the tube, one tube broken don't influence the system working 
6.The design for inner tank is reasonable and scientific, which could hold 100, 000 times fatigue test without any damage
7.Dual-purpose brackets for both flat and inclined roof

8.The system is pressurized,it keep a constant temperature of water in the tank, avoid the problem came from water level controller malfunction which could cause water flow out

 

Compact pressuirzed solar water heater working principle

1.The pressurized solar water heater tank has no exhaust hole, therefore, it must bear the pressure came from tap water and hot water,when use, the hot water comes out because of water pressure.

2.Vacuum tube absorbs solar energy, and conductive copper pipe transfers the heat into the pressurized solar water heater tank. In this case, the water inside the tank becomes hot

3.No water in the heat pipe makes the whole system could bear pressure

split_diagram_heat[1].jpg

 Description

 Compact pressurized solar water heater

 Material of out tank

 0.31-0.4mm thickness color steel/ fluorine carbon steel

 Material of inner tank

 Food grade 1.2-2.0 mm thickness SUS304 stainless steel

 Tank insulating layer

 55mm 45kg/m³ high-density polyurethane foamed

 Inlet and outlet hole

 Male G 1/2, 3/4

 Max pressure

 0.6Mpa

 Solar collector tube

 3.3 Borosilicate glass with N/Al coating

 Thickness of glass tube

 1.6mm

 Vacuum tube tightness

 P<=0.005 Pa

 Absorption

 as=0.93-0.96(AM1.5)

 Emission ratio

 0.04-0.06(80C+-5C)

 Idle sunning property parameters

 Y=220~260m2.C/KW

 Average heat loss coefficient

 ULT=0.6~0.7W/(m2.C)

 Bracket:

 2.0mm thickness aluminium alloy

 Heat pipe power

 >120W/pcs

 Heat pipe material

 0.6mm thickness TU1 copper

 Heat pipe size

 Dia14mm x 90mm length condenser, 170cm length in total

 Absorber area

 2.249m²

 Tube quantity

 24 tube 58x1,800mm with heat pipe

 Tank capacity

 200L